Variable ID
TAIR
Variable Type
Standard - Primary
Variable Category
Air Temperature
Standard Units
degrees Celsius (°C)
Description
The 5-minute average air temperature at a height of 1.5 meters above the ground.
- This sensor is quite rugged and accurate. Prior to 2009, the sensor was housed in a naturally-ventilated radiation shield. Such shields can create temperature errors of several degrees Celsius when the wind is calm (less than 1 m/s) and solar radiation is high.
- Since 2009, the sensor is housed in an aspirated radiation shield, which continuously draws ambient air over the sensor, while protecting it from solar radiation.
Accuracy
± 0.5 °C
Sensors
RM Young 41342 Platinum RTD Probe (2017–present)
Thermometrics Air Temperature (2004–2017)
Vaisala HMP35C (1994–2003)
Documentation Links
Sensor Image URL
https://content.prod.mesonet.org/repos/instruments/images/rm-young-41342.jpg
Sensor Image Alt Text
RM Young 41342 Platinum RTD Probe